Cuadernos de Medicina Forense

43 CUADERNOS DE MEDICINA FORENSE AS O C I AC I Ó N D E M É D I C O S FO R E N S ES D E A N DA LU C Í A S O C I E DA D A N DA LU Z A D E M E D I C I N A L EG A L Y C I E N C I AS FO R E N S ES ( A M FA- SA M E LC I F ) DISCREPANCIAS ENTRE BLUE STAR FORENSIC, HEXAGON OBTI Y ADN HUMANO EN UN CASO DE ASESINATO DISCREPANCIES BETWEEN BLUE STAR FORENSIC, HEXAGON OBTI AND HUMAN DNA IN A MURDER CASE Joaquín Álvaro Vázquez 1 1. Especialista en Criminalística formado en Guardia Civil. Resumen Se presenta un caso de asesinato en España en el que el reactivo presuntivo Bluestar Forensic mostró quimioluminiscencia intensa en patrones hemá- ticos del dormitorio, mientras que el inmunoensayo Hexagon OBTI resultó negativo y el análisis de ADN confirmó un perfil completo coincidente con la víctima. De 53 muestras procesadas, 18 reveladas exclusivamente por quimioluminiscencia presentaron falsos negativos en la prueba de certeza. Las causas principales fueron dilución por el propio reactivo, tipo de hisopo (algodón) y técnica de muestreo. La integración de los resultados permitió validar la naturaleza hemática del indicio y reconstruir el escenario principal de la agresión. Se proponen modificaciones metodológicas (evaporación previa del reactivo y uso de hisopos flocados) para minimizar falsos negati- vos en inmunoensayos. Abstract A homicide case in Spain is presented in which the presumptive reagent Bluestar Forensic produced intense chemiluminescence on bloodstain patterns in the bedroom, while the Hexagon OBTI immunoassay was negative and DNA analysis confirmed a complete profile matching the victim. Of 53 processed samples, 18 revealed exclusively by chemilu- minescence showed false negatives in the confirmatory test. The main causes were dilution by the reagent itself, swab type (cotton) and sam- pling technique. Integration of the results validated the haematic nature of the evidence and reconstructed the primary scene of the assault. Methodological modifications (prior evaporation of the reagent and use of flocked swabs) are proposed to minimise false negatives in immu - noassays. Palabras clave: Bluestar Forensic; Hexagon OBTI; Falso negativo; Inmunoensayo; ADN forense; Patrones hemáticos; Marcador de evento. Enviado: 18.01.26 | Revisado: 22.03.26 | Aceptado: 07.04.26 DOI: 10.59457/cmf.2025.28.02 .cc04 Cuad Med Forense. 2025; 28(2):43- 48 C A S O C L Í N I C O Key words: Bluestar Forensic; Hexagon OBTI; False negative; Immunoassay; Forensic DNA; Bloodstain patterns; Event marker. Correspondencia: Joaquín Álvaro Vázquez E-mail: joaquinalvaro@hotmail.es

RkJQdWJsaXNoZXIy ODI4MTE=